TPI contact temperature testers are accurate, reliable, and built to last. Models 341K, 343 and 367D can be auto field calibrated to system accuracy (tester plus probe) of +/- 1°F in less than 10 seconds in ice water.
AUTO FIELD CALIBRATION - Perform ice bath calibration to achieve ±1°F system accuracy within the 30°F to 120°F temperature range. Calibration is an easy two-step process performed with instrument keypad, no additional tools needed.
Model
|
Description
|
Additional Info
|
340:
|
340: -40 to +1,200 °F range, single button operation, uses K-type thermocouple with sub-mini connector
|
Instruction Manual
Data Sheet
|
341K:
|
341K: -58 to 2,462 °F (-50 to 2,462 °C) range; Auto Field Calibrate to a system accuracy (Tester plus Probe) of +/- 1 °F in less than 10 seconds in ice water; C/F; Min-Max and hold features, uses K-type thermocouple with sub-mini connector
|
Instruction Manual
Data Sheet
Auto-Cal
|
|
|
|
343:
|
343: -58 to 2,462 °F (-50 to 2,462 °C) range; Auto Field Calibrate to a system accuracy (Tester plus Probe) of +/- 1 °F in less than 10 seconds in ice water; C/F; Min-Max and hold features, uses K-type thermocouple with sub-mini connector
|
Instruction Manual
Data Sheet
Auto-Cal
|
351:
|
351: -40 to 220°F range (351X = -40 to 104°C) +/- 1 °F system accuracy (tester and probe) over 32 to 158°F range, single button, thermistor probe with bipolar connector
|
Instruction Manual
Data Sheet
|
353:
|
353: -40 to 220°F range +/- 1°F accuracy (thermistor), -328°F to 750°F range 0.3% basic accuracy (T-type thermocouple), single button operation, uses thermistor probe or T-type thermocouple with Lumberg connector
|
Instruction Manual
Data Sheet
|
354:
|
354: -40 to 220°F range +/- 1.8°F accuracy (thermistor), -328°F to 750°F range 0.3% basic accuracy (T-type thermocouple), Min/Max Record, °C/°F Selectable, uses thermistor probe or T-type thermocouple with Lumberg connector
|
Instruction Manual
Data Sheet
|
365:
|
365:
-328°F to 1112°F (-200°C to 600°C) range0.1% basic tester accuracy, waterproof IP67, uses K-type thermocouple with sub-mini connector
|
Instruction Manual
Data Sheet
|
367D:
|
367D: -58°F to 302°F (-50°C to 150°C) range (thermistor), -328°F to 1112°F (-200°C to 600°C) range (K-type thermocouple), -328°F to 752°F (-200°C to 400°C) range (T-type thermocouple), Auto Field Calibrated to a system accuracy (Tester plus Probe) of +/- 1 °F in less than 10 seconds in ice water; uses Thermistor, K-type, or T-type probes with Lumberg connectors, stores 16 readings, optional data logging software and accessories to data log 16,000 readings with sample interval from 1 second to 24 hours.
Data logging interface and software (A367) sold separately
|
Instruction Manual
Data Sheet
Auto-Cal
|
|