Contact Temperature Testers From TPI (Test Products International)

TPI contact temperature testers are accurate, reliable, and built to last. Models 341K, 343 and 367D can be auto field calibrated to system accuracy (tester plus probe) of +/- 1°F in less than 10 seconds in ice water.

AUTO FIELD CALIBRATION - Perform ice bath calibration to achieve ±1°F system accuracy within the 30°F to 120°F temperature range. Calibration is an easy two-step process performed with instrument keypad, no additional tools needed.

Model

Description

Additional Info


340:
Contact, Temperature, Testers, TPI, Test Products International

340: -40 to +1,200 °F range, single button operation, uses K-type thermocouple with sub-mini connector

Instruction Manual

Data Sheet

341K:

341K: -58 to 2,462 °F (-50 to 2,462 °C) range; Auto Field Calibrate to a system accuracy (Tester plus Probe) of +/- 1 °F in less than 10 seconds in ice water; C/F; Min-Max and hold features, uses K-type thermocouple with sub-mini connector

Instruction Manual

Data Sheet

Auto-Cal

     
343:

343

343: -58 to 2,462 °F (-50 to 2,462 °C) range; Auto Field Calibrate to a system accuracy (Tester plus Probe) of +/- 1 °F in less than 10 seconds in ice water; C/F; Min-Max and hold features, uses K-type thermocouple with sub-mini connector

Instruction Manual

Data Sheet

Auto-Cal

351:
351

351: -40 to 220°F range (351X = -40 to 104°C) +/- 1 °F system accuracy (tester and probe) over 32 to 158°F range, single button, thermistor probe with bipolar connector

Instruction Manual

Data Sheet

353:
353

353: -40 to 220°F range +/- 1°F accuracy (thermistor), -328°F to 750°F range 0.3% basic accuracy (T-type thermocouple), single button operation, uses thermistor probe or T-type thermocouple with Lumberg connector

Instruction Manual

Data Sheet

354:
354

354: -40 to 220°F range +/- 1.8°F accuracy (thermistor), -328°F to 750°F range 0.3% basic accuracy (T-type thermocouple), Min/Max Record, °C/°F Selectable, uses thermistor probe or T-type thermocouple with Lumberg connector

Instruction Manual

Data Sheet

365:
365

365: -328°F to 1112°F (-200°C to 600°C) range0.1% basic tester accuracy, waterproof IP67, uses K-type thermocouple with sub-mini connector

Instruction Manual

Data Sheet

367D:

367D: -58°F to 302°F  (-50°C to 150°C) range (thermistor), -328°F to 1112°F (-200°C to 600°C) range (K-type thermocouple), -328°F to 752°F (-200°C to 400°C) range (T-type thermocouple), Auto Field Calibrated to a system accuracy (Tester plus Probe) of +/- 1 °F in less than 10 seconds in ice water; uses Thermistor, K-type, or T-type probes with Lumberg connectors, stores 16 readings, optional data logging software and accessories to data log 16,000 readings with sample interval from 1 second to 24 hours.

Data logging interface and software (A367) sold separately

Instruction Manual

Data Sheet

Auto-Cal