TPI offers Digital Multimeters to fit a wide range of applications including electrical, electronic, commercial, HVAC/R, and industrial.
460
|
The 460 hand held oscilloscope features a 3" x 3" cold cathode fluorescent display providing test data in a clear easy to see format. The cursor readout function allows the width and amplitude of a signal to be measured precisely instead of trying to figure it out manually.
- 4,000 count true RMS DMM, CACV, DCV ohms and continuity buzzer need optional adapters for current measurement
- 20 MHz Bandwidth
- Cursor Readout
- Decibels
- Pre and Post Triggering
- Trend Mode
- Dual Input
- Real Time Sample Rate
- Bright LCD Backlight
- Optically Isolated RS232 Output
- Continuous Autoset
- cULus 61010-1
- CAT II - 1000V, CAT III - 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual
|
|
|
|
440
|
The hand held 440 scope plus features an easy to use combination of a single input 1 MHz oscilloscope with True RMS DMM.
- True RMS Auto Ranging DMM offers increased accuracy over average responding multimeters
- 1MHz Oscilloscope can be used to view power signals to determine quality as well as correct amplitude and frequency, assisting in finding and preventing problems
- Trend Mode enables surges and dropouts to be graphed.
- Communication to a PC using optional RS-232 cable and software
- cULus 61010-1
- CAT II - 1000V, CAT III - 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual
|
|
|
|
196
|
0-24 mA output built in for process loop calibration, 0.05% accuracy, 50,000 counts, DMM with separate fuse and battery compartment
- Process DMM with 0 to 24mA output
- 50,000 count display
- 0.05% DCV basic accuracy
- 0 to 750 ACV; max resolution 100uV
- 0 to 1,000 DCV; max resolution 0.001mV
- 0 to 50MΩ; max resolution 0.01Ω
- Audible continuity
- AC/DC amps up to10 amps; max resolution 0.01uA
- Analog bar graph
- Min/Max
- Data hold
- Power off
- Separate fuse and battery compartment
- cULus 61010-1
- CAT II-1000VDC, 750VAC, CATIII-600V
- Limited Life time Warranty
|
Product Sheet
nstruction Manual
|
|
|
|
194
|
CAT IV 600 ACV, data logging, 0.05% accuracy, 50,000 count, True RMS DMM with separate fuse and battery compartment
- Data logging
- 50,000 count display
- 0.05% DCV basic accuracy
- True RMS
- Inductance
- Frequency
- Capacitance
- 0 to 750 ACV; max resolution 100uV
- 0 to 1,000 DCV: max resolution 0.001mV
- 0 to 50MΩ max resolution 0.01Ω
- Audible continuity
- AC/DC amps up to10 amps; resolution 0.01 uA
- Analog bar graph
- Min/Max
- Data hold
- Power off
- Separate fuse and battery compartment
- cULus 61010-1
- CATIII-1000VC, CATIII-1000V, CAT IV-600V, CAT III 1000V
- Limited Life time Warranty
|
Data Sheet
Instruction Manual
|
|
|
|
192
|
Data logging, 0.05% accuracy, 50,000 count, True RMS DMM with separate fuse and battery compartment.
- Data logging
- 50,000 count display
- 0.05% DCV basic accuracy
- True RMS
- Inductance
- Frequency
- Capacitance
- 0 to 750 ACV; max resolution 100uV
- 0 to 1,000 DCV: max resolution 0.001mV
- 0 to 50MΩ max resolution 0.01Ω
- Audible continuity
- AC/DC amps up to10 amps; resolution 0.01 uA
- Analog bar graph
- Min/Max
- Data hold
- Power off
- Separate fuse and battery compartment
- cULus 61010-1
- CAT II-1000VDC, 750VAC, CAT III - 600V
- Limited Life time Warranty
|
Product Sheet
Instruction Manual
|
|
|
|
183A
|
True RMS DMM with temperature, capacitance, duty cycle, & low-pass filter
4,000 count
True RMS for more accurate measurements
Auto/manual ranging
Temperature measurement
Duty cycle to measure the amount of time the motor is on
Low pass filter for noisy environments
Separate fuse (2) and battery compartment
Auto power off
IR serial interface
cULus 61010-1
CAT II - 1000V, CAT III - 600V
3 Year Limited Warranty
Applications
Test run and start capacitors
Measure ambient and duct temp.
Test control (thermostat, thermocouple, flame safety) and line voltages
Measure resistance and test for continuity
Line current up to 10 amps (in series)
|
Data Sheet
Instruction Manual
|
|
|
|
163
|
Full size DMM with analog bar graph; 1,000 DC volts and 750 AC volts; 0.5% DCV basic accuracy
- 3260 count display
- 0.5% DCV basic accuracy
- 0 to 750 ACV; max resolution 1mV
- 0 to 1,000 DCV; max resolution 0.1mV
- 0 to 32.6MΩ max resolution 0.1Ω
- Audible continuity
- 0 to 10 amps AC/DC; max resolution 0.1uA
- Analog bar graph
- Data hold
- Sleep mode/auto off
- cULus 61010-1
- CAT II - 1000V, CAT III - 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual
|
|
|
|
153
|
Full size, autoranging, easy to read, 0.3% DCV basic accuracy DMM; 1,000 DC volts and 750 AC volts
- 0.3% DCV basic accuracy
- 0 to 750 ACV; max resolution 1mV
- 0 to 1,000 DCV: max resolution 0.1mV
- 0 to 40MΩ max resolution 0.1Ω
- AC/DC amps to 10; max resolution 0.1uA
- Min/Max
- Data hold
- Sleep mode/auto off
- cULus 61010-1
- CAT II - 1000V, CAT III - 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual
|
|
|
|
135
|
Full size DMM with capacitance; 1,000 DC volts and 750 AC volts; 0.5% DCV basic accuracy
- 4,000 count display
- 0.5% DCV basic accuracy
- 0 to 750 ACV; max resolution 0.1mV
- 0 to 1,000 DCV; max resolution 0.1mV
- 0 to 40MΩ max resolution 0.1Ω
- 0 to 10 amps AC/DC; 0.1uA resolution
- Data hold
- cULus 61010-1
- CAT II - 1000V, CAT III - 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual
|
|
|
|
133
|
Large easy to read display in full size DMM; 1,000 DC volts and 750 AC volts; 0.5% DCV basic accuracy
- Large easy to read 2,000 count display
- 0.5% DCV basic accuracy
- 0 to 750 ACV; max resolution 1mV
- 0 to 1,000 DCV; max resolution 0.1mV
- 0 to 20MΩ max resolution 0.1Ω
- 0 to 10 amps AC/DC; max resolution 0.1uA
- Data hold
- cULus 61010-1
- CAT II - 1000V, CAT III - 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual
|
|
|
|
126
|
Compact autoranging DMM with 0.3% DCV basic accuracy and 400mA AC/DC range
- 4,000 count display
- 0.3% DCV basic accuracy
- 0 to 600 volts AC/DC; max resolution 0.1V
- 0 to 40MΩ resistance; max resolution 0.1Ω
- Audible continuity
- 0 to 400 mA amps AC/DC; max resolution 0.01mA
- Autoranging
- Min/Max
- Data Hold
- Sleep mode/auto off
- cULus 61010-1
- CAT II - 1000V, CAT III - 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual
|
|
|
|
122
|
Compact DMM with adapter range for optional accessories, 0.5% DCV basic accuracy
- 2,000 mvDC (2 DCV) adapter range
- 2,000 count display
- 0 to 600 volts AC and DC
- 0 to 2,000 ohms
- Audible continuity
- 10 MOHM internal impedance
- 0.5 % DCV basic accuracy
- cULus 61010-1
- CAT II - 1000V, CAT III - 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual
|
|
|
|
120
|
Compact, manual ranging, basic DCV 0.5% accuracy DMM
- 2,000 count display
- 0 to 600 volts AC and DC
- 0 to 2,000 ohms
- Audible continuity
- 10 MOHM internal impedance
- 0.5% DCV basic accuracy
- cULus 61010-1
- CAT II - 1000V, CAT III - 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual
|
|
|
|
100
|
No more guessing what range to switch your meter to the TPI 100 does it automatically!
- Automatically switches between ACV, DCV, and ohms (resistance). Benefit Simple to use. Meter selects function and range, just connect the leads to the device under test.
- Single button operation. Benefit EZ to use. Enables users with limited knowledge to perform tests safely.
- 0 to 600 volts AC and DC Benefit Enough range to safely perform measurements
- 10 MΩ internal impedance. Benefit High impedance prevents inaccurate reading caused by circuit loading.
- Auto power off. Benefit Increases battery life by turning off the multimeter when not in use.
- 4,000 count display
- Up to 40MΩ
- cULus 61010-1
- CAT II 1,000-V / CATIII 600V
- 3 Year Limited Warranty
|
Product Sheet
Instruction Manual
|